Load Cell (Strain Gauge) 50kg Sensor Micro Scale Half-bridge Weighing Sensor
Features
Internal half-bridge strain gauge load cell range is 50KG, half-bridge structure.
Dimensions: 28mm * 28mm
Installation: suspended above the middle on both sides of the fixed platen force output voltage signal
Surface -scale output voltage = excitation voltage x sensitivity 1.0mv / v
Note:
Please see the instructions for use, applying pressure means press the “direction of the force ” schematically the correct force is applied ; the E-shaped intermediate portion of the sensor and the two side edges to form a shear force in the opposite direction .
Wiring:
Reverse direction by the force2 sensor allows a group of two sensor black and black to blue and blue then do the output signal, sensor 2 red one do with an input voltage as input voltage +-
Force in one direction Two sensors connected blue and black blue and red a black pick two sensor input voltage + one do to make the input voltage –
The internal sensor is a half-bridge strain gauge group, use the following three methods:
Method (1): Use a sensor with an external resistor full bridge measurement range is a range of the sensor: 50KG For external resistors require a higher (Not recommended to buy)
Method (2): Using two sensors full bridge measurement with two sensors and a range of: 50KG * 2 = 100kg
Method (3): Use the four full-bridge sensors measuring range is four sensor range of: 50KG * 4 = 200kg
Specifications:
Range (kg) | 50 | ||
Comprehensive error (% F.S) | 0.2 | Rated output temperature drift (% F.S/10 ) | ≤0.15 |
Sensitivity (mv / v) | 0.9 ±0.1 | Zero output (mV / V) | ± 0.3 |
Nonlinearity (% F.S) | 0.2 | Input resistance (Ω) | 1000 ± 50 |
Repeatability (% F.S) | 0.1 | Output resistance (Ω) | 1000 ± 50 |
Hysteresis (% F.S) | 0.2 | Insulation Resistance (MΩ) | ≥ 2000 (100VDC) |
Creep (% F.S/3min) | 0.1 | Recommended excitation voltage (V) | 5 ~ 10 |
Zero drift (% F.S/1min) | 0.1 | Operating temperature range () | -10 To +50 |
Zero temperature drift (% F.S/10 ) | 0.2 | Overload (% F.S) | 150 |
Package Includes:
1 x Load Cell (Strain Gauge) 50kg Sensor